  ge preliminary data sheet october 11, 2013 ?2012 general electric corporation. all rights reserved. CLP0212 open frame power supply 90 - 264vac input; 12 vdc output; 200w output power features ? compact size 50.8 mm x 101.6 mm x 3 6.1 mm (2 in x 4 in x 1.4 in) with density of 18w/in 3 ? universal ac input range (90 C 264vac) ? output voltage of 12v (adjustable 5%) ? maximum output current of 16.7 a @ 12vout (200w) ? st andby output of 5v or 3.3v @ 0. 2 5a ? high efficiency with 80 plus? gold certification ? full load capability at 50oc and 1m/s (200lfm) airflow with derating at higher temperatures or lower airflows ? remote on/off ? output overcurrent protection (non - latching) ? overtemperature protection ? output overvoltage protection ? u p to 12ms of holdup time ? parallellable with current sharing ? active power factor corrected input ? conducted emi - meets cispr22 (en55022) and fcc class a requirements ? compliant to rohs eu directive 2002/95/ec ? ul and cul approved to ul/csa60950 - 1, tuv (en60950 - 1), ce mark (for lvd) and cb report available ? iso** 9001 and iso 14001 certified manufacturing facilities applications ? telecommunications equipment ? embedded computing ? storage systems ? industrial equipment description i n a small 2 x 4 inc h footprin t, th e 12v d c single - outpu t CLP0212 ope n fram e po w e r suppl y deli v e r s 80 p l us gol d ene r g y efficiency . with its small size, t he cl p serie s i s specificall y designe d t o handle po w e r challenge s associate d wit h tight spac e an d lo w ai r flo w . offerin g a leading 18w/in 3 po w e r densit y i n a 1 u high , fan - less for m facto r , th e cl p serie s add r esse s a b r oa d rang e o f application s i n ne w p r oducts f r o m communications , computin g an d data storag e origina l equipmen t manufactu r e r s (oems). it deli v e r s g r eate r tha n 9 0 pe r cen t typica l po w er efficienc y an d f ul l loa d outpu t a t +50?c (122?f ) wit h higher temperature operation possible at derated output . th e cl p serie s utilize s a uniqu e desig n app r oac h a t thi s po w e r le v el, le v eragin g ze r o v oltag e switchin g techniques i n conjunctio n wit h quasi - r esonan t po w er facto r cor r ectio n (pfc ) ci r cuits . p r otectio n featu r e s includ e o v e r cur r en t (ocp), o v e r v oltag e ( o vp) , an d o v e r temperatu r e ( o tp) . * ul is a registered trademark of underwriters laboratories, inc. ? csa is a registered trademark of canadian standards association. ? vde is a trademark of verband deutscher elektrotechniker e.v. ** iso is a registered trademark of the international organizat ion of standards
ge preliminary data sheet CLP0212 open frame power supply 90 - 264vac input; 12 vdc output; 200w output power october 11, 2013 ?2012 general electric corporation. all rights reserved. page 2 absolute maximum ratings stresses in excess of the absolute maximum ratings can cause permanent damage to the device. these are absolute stress rating s only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. exposure to absolute maximum ratings for extended periods can adversely affect the device reliabi lity. parameter device min max unit input voltage - continuous all 90 264 v ac operating ambient temperature all - 25 70 c (see thermal considerations section) CLP0212fp e x5z01a - 40 ? 70 c CLP0212fpe xz02a CLP0212fpe x 5 z0 3 a - 40 ? 85* c (in sealed enclosure applications with thermally conductive pad to enclosure, p o,max = 65w) CLP0212fpe x 5 z02a - 40 55 ? c (in sealed enclosure applications with thermally conductive pad to enclosure, p o,max = 110w) CLP0212fpe x 5 z0 3 a - 40 55 ? c storage temperature all - 40 8 5 c humidity (non - condensing) all 5 95 % altitude all 4000 m ? startup at - 40oc is limited to 80% of maximum load (160w) for all versions, except the CLP0212fpe xz02a w hich can start up at full load. * unit is capable of operation up to 85oc ambient for brief periods of time provided humidity is kept b elow 40%. sustained operation at 85oc when input voltage is above 230vac and output power loading is at or near the maximum rated value can degrade reliability of the product. ? ambient temperature outside the sealed enclosure containing the power supply. electrical specifications parameter device min typ max unit operating input voltage all 90 115/230 264 va c input source frequency all 47 50/60 63 hz input current (v in = 90vac) all versions except CLP0212fpe xz02a 4 a rms CLP0212fpe xz02a 1.6 a rms input power factor all 0.95 inrush transient current (v in = 264vac , t amb = 25oc) all 100 a peak leakage current to earth ground (v in = 264vac) all 2 ma output voltage setpoint all 12 vdc output voltage tolerance (due to set point, temperature variations, load and line regulation) all - 2 2 % output voltage adjustment range all 11. 4 12.6 vdc output remote sense range all 250 m vdc output load regulation all 1 .5 %vout output line regulation all 0.5 %vout output ripple and noise C measured with 0.1f ceramic capacitor in parallel with 10f tantalum capacitor , at 25c 1 peak - to - peak (20mhz bandwidth) all 1 8 0 mv p - p dynamic load response C 50% to 75 % load transient, 0. 1a/s slew rate output voltage deviation settling time all all 5% 500 % s output current all versions except CLP0212fpe xz02a 0 16.7 adc output current CLP0212fpe xz02a 0 8.34 adc output current limit inception all 115 % i o,max 1 output ripple is 300mv p - p maximum at - 40c. to reduce further, additional external capacitance needed.
ge preliminary data sheet CLP0212 open frame power supply 90 - 264vac input; 12 vdc output; 200w output power october 11, 2013 ?2012 general electric corporation. all rights reserved. page 3 electrical specifications (cont.) parameter device min typ max unit maximum output capacitance all 5000 f standby output voltage CLP0212fpxx5z01a CLP0212fp e x5z01a 5 vdc CLP0212fpxx3z01a 3.3 vdc standby output current all 0.25 adc efficiency: v in = 230vac, 20% load all except ..z02a 86.8 % 50% load all except ..z02a 91.1 % 100% load all except ..z02a 89.5 % v in = 115vac, 20% load all except ..z02a 89.2 % 50% load all except ..z02a 90.3 % 100% load all except ..z02a 87.1 % holdup time C v in = 115vac, 100% load 2 65w load for CLP0212fpe xz02a all except ..z02a CLP0212fpe xz02a 10 45 ms v in = 230vac, 100% load 65w load for CLP0212fpe xz02a all except ..z02a CLP0212fpe xz02a 10 45 ms isolation specifications parameter device min max unit isolation voltage C input to output all 3000 vac input to safety ground all 1500 vac outputs to safety ground all 50 vac general specifications parameter device symbol typ. unit calculated reliability based on telcordia sr - 332 issue 2: method 1 case 3 (v in =230vac, i o = 16.7a, t a = 40oc, airflow 200lfm, 90% confidence) all fit mtbf 1,011.9 988,276 10 9 /hours hours weight all 185 6.5 g oz. feature specifications parameter device min typ max unit on/off signal interface C signal referenced to gnd logic low (power supply on) input low current all 7 ma input low voltage all 1 v logic high (power supply off) input high current all 600 a input voltage all 5.5 v delay from on/off being enabled to start of output voltage rise all 50 ms output voltage rise time (from 10 to 90% of final value) all 5 ms delay from input being applied to standby output being in regulation all 12 ms delay from input being applied to all outputs being in regulation all 30 ms output holdup time (from loss of ac to output being out of regulation) all 1 0 ms output overvoltage protection (for main output currents above 0.1a) all 13.8 1 8 vdc 2 holdup time is reduced at cold temperatures
ge preliminary data sheet CLP0212 open frame power supply 90 - 264vac input; 12 vdc output; 200w output power october 11, 2013 ?2012 general electric corporation. all rights reserved. page 4 feature specifications (cont.) parameter device min typ max unit input undervoltage lockout 3 turn - on threshold (100% load) all 86 vac turn - off threshold (100% load) all 82 vac dc ok C open collector, high when output available sink current all 4 ma maximum collector voltage all 12 v enviro nmental specifications parameter device specification conducted emissions all cispr22 (en55022) class a with 3db margin input harmonics all en61000 - 3 - 2 esd all iec 61000 - 4 - 2, level 3 radiated immunity all iec 61000 - 4 - 3, level 2 * electrical fast transient common mode all iec 61000 - 4 - 4, level 3 surge immunity all iec 61000 - 4 - 5, level 3 conducted rf immunity all iec 61000 - 4 - 6, level 3 voltage dips all en61000 4.11, level 3, class b, c shock and vibration operating shock all three shocks, 15g peak, 11ms sine wave, two axes non - operating shock all three shocks, 50g peak, 11ms sine wave, two axes operating and non - operating vibration all 5 C 9hz, 0.5 double amplitude, 2g peak, 0.5 oct./min., 2 cycles 9 - 500hz, 4g pk - pk , 0.5 oct/min., 2 cycles * radiated immunity is met when the power supply is tested in a suitable enclosure. 3 the undervoltage lockout thresholds vary with output load current level C decreasing as the load goes down
ge preliminary data sheet CLP0212 open frame power supply 90 - 264vac input; 12 vdc output; 200w output power october 11, 2013 ?2012 general electric corporation. all rights reserved. page 5 characteristic curves the following figures provide typical characteristics for CLP0212 power supply efficiency, (%) output current, io (a) output load % ambient temperature, t a o c figure 1. power supply efficiency versus output current. figure 2. derating output current versus ambient temperature and airflow. data shown for 115vac in, at 230vac in derating is the same or better. for derating at other input voltages, consult the ge technical representative. output voltage v o (v) ( 5 0mv/div) output current, output voltage i o (a) (10 adiv) v o (v) ( 100 mv/div) time, t ( 10m s/div) time, t ( 5m s /div) figure 3. typical output ripple and noise (v in = 230 v ac , 100% load ). figure 4. transient response to dynamic load change from 50% to 100% at vin = 230vac. out put voltage in put voltage v o (v) (2 v/div) v in (v) (200 v/div) output voltag e input voltage v o (v) (2 v/div) v in (v) ( 200 v/div) time, t ( 10 ms/div) time, t ( 10 ms/div) figure 5. typical start - up (v in = 115 v ac) . figure 6. typical start - up (v in = 230 v ac) 80 82 84 86 88 90 92 94 0 2 4 6 8 10 12 14 16 18 vin=115vac vin=230vac 0 5 10 15 20 30 35 40 45 50 55 60 65 70 0.5m/s (100lfm) 2m/s (400lfm) 1m/s ( 200lfm ) nc
ge preliminary data sheet CLP0212 open frame power supply 90 - 264vac input; 12 vdc output; 200w output power october 11, 2013 ?2012 general electric corporation. all rights reserved. page 6 characteristic curves (cont.) the following figures provide typical characteristics for CLP0212 power supply output voltage input voltage v o (v) (2v/div) v in (v) (200 v/div) output voltage input voltage v o (v) (2v/div) v in (v) (200 v/div) time, t ( 10 ms/div) time, t ( 10 ms/div) figure 7 . typical hold - up waveforms (v in = 115 v, 100% load ). figure 8 . typical hold - up waveforms (v in = 230 v, 100% load ).
ge preliminary data sheet CLP0212 open frame power supply 90 - 264vac input; 12 vdc output; 200w output power october 11, 2013 ?2012 general electric corporation. all rights reserved. page 7 safety considerations th e cl p 0212 po w e r suppl y i s intende d for inclusio n i n othe r equipmen t an d th e installe r mus t ensu r e tha t i t i s i n complianc e wit h al l th e r equi r ement s of th e en d application . thi s p r oduc t i s onl y for inclusio n b y p r ofessiona l installe r s withi n othe r equipmen t an d mus t no t b e operate d a s a stand - alone p r oduc t . th e po w e r suppl y meets clas s 1 , iec60950 , en60950 , wit h th e followin g deviations : nemk o . u l 6095 0 ( r ecognize d component ) c - ul (canadia n app r o v a l b y ul) . feature descriptions standby power supply a standby output in the CLP0212 power supply of either 3.3 or 5v, comes on when ac input in the operating range is applied. in the z02a and z03a versions of the power supply, the standby output is not accessible. remote on/off all versions of the CLP0212 power supply except the z02a and z03a versions feature a ttl - compatible on/off control input. the power supply turns on when the on/off input goes low , and turns off when the input goes high . note that if the on/off pin is left unconnected, the power supply main output remains off. figure 9 shows the circuit configuration for using the on/off pin . either a suitable semiconductor device such as a bjt or fet or a mechanical switch can be used to turn the power supply on and off. t he switch must be capable of handling the on/off pin current which may be up to 6ma when closed. the switch on voltage drop must also be sufficiently small so that the photo diode inside the power supply is turned on when the external switch is on. note that the standby output voltage could be either 3.3v or 5v depending on the CLP0212 power supply variant selec ted. if no on/off control is desired, the on/off pin can be externally connected to the com pin and the power supply will automatically turn on when ac input is within range. fig. 9. schematic showing on/off circuitry . output voltage adjustment fig. 10 . diagram showing location of the potentiometer used to adjust the power supply output voltage. the output voltage can be adjusted between 11.4v and 12.6v using a potentiometer on the power supply. see fig. 10 for a diagram showing location of the potentiometer. remote sense the power supply has both positive and negative remote sense connections that can be connected to the positive and negative rails of the main output near the load. care should be taken in routing the sense lines to ensure that noise is not picked up or that additional filtering elements that affect the stability of the power supply are not used. the power supply will operate without the remote sense connections being made , however if remote sense near the load is not used it is recommended that the remote sense lines be connected directly to the main output terminals. overcurrent protection to provide protection in a fault condition (output overload), the power supply is equipped with internal current - limiting cir cuitry and can endure current limiting continuously. at the point of current - limit inception, the unit enters hiccup mode. the power supply operates normally once the output current is brought back into its specified range. overvoltage protection overvolta ge protection is a feature of the CLP0212 power supply that protects both the load and the power supply from an output overvoltage condition. when an overvoltage occurs, the power supply shuts down and goes into hiccup mode until the overvoltage condition is removed. it is not necessary to recycle the input to restart the power supply when this protection is activated. overtemperature protection the CLP0212 also features overtemperature protection in order to provide additional protection in a fault condit ion. the power supply is equipped with a thermal shutdown circuit which detects excessive internal temperatures and shuts the unit down. once the power supply goes into overtemperature shutdown, it will cool before attempting to restart. the overtemperatur e protection circuit will typically activate when the unit is operated at 200w output with an ambient temperature of 60oc and 1m/s (200lfm) airflow. 1 2 5 4 3.65k 1k switch 1 2 standby output com on/off clp power supply potent iometer
ge preliminary data sheet CLP0212 open frame power supply 90 - 264vac input; 12 vdc output; 200w output power october 11, 2013 ?2012 general electric corporation. all rights reserved. page 8 input undervoltage lockout at input voltages below the input undervoltage lockout limit, power supply operation is disabled. the power supply will begin to operate at an input voltage above the undervoltage lockout turn - on threshold. note that the undervoltage lockout limits are load dependent and the power supply turns on and can operate at much lower input voltage levels when at light or no load. dc ok the CLP0212 provides a dc ok signal that indicates when the output has come up and is in regulation. this is an open - collector type signal that goes high when the output is avai lable and within regulation . power good led a green led (located next to hdr3) illuminates when the main output voltage is above 10v. paralleling/load share this power supply can be paralleled to provide larger load currents than can be delivered from a single power supply. up to four power supplies may be paralleled. paralleling is accomplished by connecting the current share signals of multiple power supplie s together. at load current levels above 20%, the output currents of multiple power supplies will be within 5% of the full load value. if remote sense is used when paralleling is employed, the remote sense connection points should be common to both power supplies. for applications where redundancy among paralleled power supplies is desired, oring diodes or other active oring circuitry needs to be connected in series with each output. thermal considerations th e po w e r suppl y can be operated in a variety of thermal environments; however sufficient cooling should be provided to ensure reliable operation. considerations include ambient temperature, airflow, power supply dissipation and the need for increased reliability. a reduction in the operating temperatur e of the power supply will result in increased reliability. the thermal data presented here is based on measurements taken in a wind tunnel. heat transfer via convection increased airflow through the power supply enhances the heat transfer via convection . figure 11 shows the preferred airflow direction. contact your ge energy technical representative for derating information in other airflow directions. note: under natural convection cooling conditions, the maximum load is restricted to 100w as otp will be triggered at higher loads. fig. 11. preferred airflow direction for cooling. operation in a sealed enclosure the CLP0212 power supply can also be operated in a sealed enclosure provided proper means for removing heat from the power suppl y are used. figure 12 shows an arrangement where a thermally conductive pad is used to transfer heat from the bottom of the power supply into the enclosure. under such conditions, the power supply is capable of reduced power operation as shown in table 1. fig. 1 2 . example arrangement of the CLP0212 for sealed enclosure applications. table 1 . output power capability when the CLP0212 is operated in a sealed enclosure with thermal pad for conduction cooling. ambient temperature (oc) max. output power (w) 25 170 40 150 55 110 . enclosure wall thermally conductive pad
ge preliminary data sheet CLP0212 open frame power supply 90 - 264vac input; 12 vdc output; 200w output power october 11, 2013 ?2012 general electric corporation. all rights reserved. page 9 emi performance all CLP0212 power supplies are specified to meet conducted class a emi requirements per cispr 22 (en55022) with at least 3db of margin. results of tests conducted without any external filtering are shown below. these indicate 10db or better of margin ov er the class a limits. CLP0212fpxx5z01a (120vac in, 12v @ 180w out, n egative of output grounded) CLP0212fpxx5z01a (208vac in, 12v @ 180w out, negative of output grounded)
ge preliminary data sheet CLP0212 open frame power supply 90 - 264vac input; 12 vdc output; 200w output power october 11, 2013 ?2012 general electric corporation. all rights reserved. page 10 CLP0212fpex5z03a (120vac in, 12v @ 180w out, negative of output grounded) CLP0212fpex5z03a (208vac in, 12v @ 180w out, negative of output grounded)
ge preliminary data sheet CLP0212 open frame power supply 90 - 264vac input; 12 vdc output; 200w output power october 11, 2013 ?2012 general electric corporation. all rights reserved. page 11 mechanical outline (all except CLP0212 z02a & CLP0212z03a versions ) dimensions are in millimeters . tolerances: x.x mm 0.5mm [unless otherwise indicated] x.xx mm 0.25mm top view side view 3d - view
ge preliminary data sheet CLP0212 open frame power supply 90 - 264vac input; 12 vdc output; 200w output power october 11, 2013 ?2012 general electric corporation. all rights reserved. page 12 mechanical outline - CLP0212fpe xz02a dimensions are in millimeters. tolerances: x.x mm 0.5mm [unless otherwise indicated] x.xx mm 0.25mm top view side view 3d - view
ge preliminary data sheet CLP0212 open frame power supply 90 - 264vac input; 12 vdc output; 200w output power october 11, 2013 ?2012 general electric corporation. all rights reserved. page 13 mechanical outline - CLP0212fpe x 5 z0 3 a dimensions are in millimeters. tolerances: x.x mm 0.5mm [unless otherwise indicated] x.xx mm 0.25mm top view side view 3d - view
ge preliminary data sheet CLP0212 open frame power supply 90 - 264vac input; 12 vdc output; 200w output power october 11, 2013 ?2012 general electric corporation. all rights reserved. page 14 connector information pinout information note: signal connector hd3 is not present in the z02a and z03a version s . connector connector on power supply mating connector ac input connector (hdr1) 5 - 1376382 - 1 from tyco or equivalent 1376 3 88 - 1 from tyco or equivalent dc output connector (hdr2) 39 - 28 - 1043 from molex or equivalent 39 - 01 - 2040 from molex or equivalent signal connector (hdr3) 53047 - 0810 from molex or equivalent 51021 - 0800 from molex or equivalent ac input connector (hdr1) dc input connector (hdr2) signal connector (hdr3) pin 1 line pin 1 vo pin 1 current share pin 2 neutral pin 2 vo pin 2 +s (remote sense +) pin 3 rtn pin 3 - s (remote sense - ) pin 4 rtn pin 4 remote on/off pin 5 dc - ok (output ok) pin 6 com (output return) pin 7 com (output return) pin 8 standby output
ge preliminary data sheet CLP0212 open frame power supply 90 - 264vac input; 12 vdc output; 200w output power contact us for more information, call us at usa/canada: +1 888 546 3243 , or +1 972 244 9288 asia - pacific: +86.021.54279977*808 europe, middle - east and africa: +49.89.878067 - 280 india: +91.80.28411633 www.ge criticalpower .com october 11, 2013 ?2012 general electric corporation. all rights reserved. version 1.26 ordering information please contact your lineage power sales representative for pricing, availability and optional features. table 2 . device codes device code input voltage range output voltage output current on/off control standby supply temperature range comcode CLP0212fpxx5z01 a 90 C 264vac 12.0vdc 16.7a negative logic 5v@0.25a - 25 to 70oc 150032000 CLP0212fpxx3z01 a 90 C 264vac 12.0vdc 16.7a negative logic 3.3v@0.25a - 25 to 70oc 150032001 CLP0212fp e x5z01 a 90 C 264vac 12.0vdc 16.7a negative logic 5v@0.25a - 40 to 70oc 150032002 CLP0212fpe x z02a 90 C 264vac 12.0vdc 8.34a absent not accessible - 40 to 70oc 150032003 CLP0212fpe x5 z03a 90 C 264vac 12.0vdc 16.7a absent not accessible - 40 to 70oc 150032004 CLP0212fpx x5z03a 90 C 264vac 12.0vdc 16.7a absent not accessible - 25 to 70oc 15003200 5